In Vitro Validation of Finite Element Analysis of Blood Flow in Deformable Models EO Kung, AS Les, CA Figueroa, F Medina, K Arcaute, RB Wicker, ... Annals of biomedical engineering 39, 1947-1960, 2011 | 131 | 2011 |
Predictive modeling of the virtual Hemi-Fontan operation for second stage single ventricle palliation: two patient-specific cases E Kung, A Baretta, C Baker, G Arbia, G Biglino, C Corsini, S Schievano, ... Journal of biomechanics 46 (2), 423-429, 2013 | 102 | 2013 |
A simulation protocol for exercise physiology in Fontan patients using a closed loop lumped-parameter model E Kung, G Pennati, F Migliavacca, TY Hsia, R Figliola, A Marsden, ... Journal of biomechanical engineering 136 (8), 081007, 2014 | 85 | 2014 |
An integrated approach to patient-specific predictive modeling for single ventricle heart palliation C Corsini, C Baker, E Kung, S Schievano, G Arbia, A Baretta, G Biglino, ... Computer methods in biomechanics and biomedical engineering 17 (14), 1572-1589, 2014 | 81 | 2014 |
In vitro validation of finite-element model of AAA hemodynamics incorporating realistic outlet boundary conditions EO Kung, AS Les, F Medina, RB Wicker, MV McConnell, CA Taylor | 81 | 2011 |
Thrombotic risk stratification using computational modeling in patients with coronary artery aneurysms following Kawasaki disease D Sengupta, AM Kahn, E Kung, M Esmaily Moghadam, O Shirinsky, ... Biomechanics and modeling in mechanobiology 13, 1261-1276, 2014 | 75 | 2014 |
Moving domain computational fluid dynamics to interface with an embryonic model of cardiac morphogenesis J Lee, ME Moghadam, E Kung, H Cao, T Beebe, Y Miller, BL Roman, ... PloS one 8 (8), e72924, 2013 | 68 | 2013 |
Development of a Physical Windkessel Module to Re-Create In Vivo Vascular Flow Impedance for In Vitro Experiments EO Kung, CA Taylor Cardiovascular engineering and technology 2, 2-14, 2011 | 65 | 2011 |
Hemodynamic effects of left pulmonary artery stenosis after superior cavopulmonary connection: a patient-specific multiscale modeling study DE Schiavazzi, EO Kung, AL Marsden, C Baker, G Pennati, TY Hsia, ... The Journal of thoracic and cardiovascular surgery 149 (3), 689-696. e3, 2015 | 50 | 2015 |
In Vitro Validation of Patient-Specific Hemodynamic Simulations in Coronary Aneurysms Caused by Kawasaki Disease E Kung, AM Kahn, JC Burns, A Marsden Cardiovascular engineering and technology 5, 189-201, 2014 | 39 | 2014 |
An interactive simulation tool for patient-specific clinical decision support in single-ventricle physiology T Conover, AM Hlavacek, F Migliavacca, E Kung, A Dorfman, RS Figliola, ... The Journal of Thoracic and Cardiovascular Surgery 155 (2), 712-721, 2018 | 36 | 2018 |
Superior performance of continuous over pulsatile flow ventricular assist devices in the single ventricle circulation: A computational study T Schmidt, D Rosenthal, O Reinhartz, K Riemer, F He, TY Hsia, ... Journal of biomechanics 52, 48-54, 2017 | 32 | 2017 |
A real-time programmable pulsatile flow pump for in vitro cardiovascular experimentation RR Mechoor, T Schmidt, E Kung Journal of biomechanical engineering 138 (11), 111002, 2016 | 30 | 2016 |
Computational modeling of pathophysiologic responses to exercise in Fontan patients E Kung, JC Perry, C Davis, F Migliavacca, G Pennati, A Giardini, TY Hsia, ... Annals of biomedical engineering 43, 1335-1347, 2015 | 27 | 2015 |
A hybrid experimental-computational modeling framework for cardiovascular device testing E Kung, M Farahmand, A Gupta Journal of biomechanical engineering 141 (5), 051012, 2019 | 26 | 2019 |
Effect of respiration on cardiac filling at rest and during exercise in Fontan patients: a clinical and computational modeling study A Van De Bruaene, G Claessen, A La Gerche, E Kung, A Marsden, ... IJC heart & vasculature 9, 100-108, 2015 | 21 | 2015 |
Integration of clinical data collected at different times for virtual surgery in single ventricle patients: a case study C Corsini, C Baker, A Baretta, G Biglino, AM Hlavacek, TY Hsia, E Kung, ... Annals of biomedical engineering 43, 1310-1320, 2015 | 17 | 2015 |
Multiscale modeling of superior cavopulmonary circulation: hemi-Fontan and bidirectional Glenn are equivalent E Kung, C Corsini, A Marsden, I Vignon-Clementel, G Pennati, R Figliola, ... Seminars in Thoracic and Cardiovascular Surgery 32 (4), 883-892, 2020 | 15 | 2020 |
Risks and benefits of using a commercially available ventricular assist device for failing Fontan cavopulmonary support: a modeling investigation M Farahmand, MN Kavarana, EO Kung IEEE Transactions on Biomedical Engineering 67 (1), 213-219, 2019 | 15 | 2019 |
Factors affecting cardiovascular physiology in cardiothoracic surgery: implications for lumped-parameter modeling J Kaufmann, E Kung Frontiers in Surgery 6, 62, 2019 | 14 | 2019 |