Seguir
Shah Mukim Uddin
Shah Mukim Uddin
Dirección de correo verificada de student.unimelb.edu.au - Página principal
Título
Citado por
Citado por
Año
A microdevice for rapid, monoplex and colorimetric detection of foodborne pathogens using a centrifugal microfluidic platform
A Sayad, F Ibrahim, SM Uddin, J Cho, M Madou, KL Thong
Biosensors and Bioelectronics 100, 96-104, 2018
1602018
A microfluidic lab-on-a-disc integrated loop mediated isothermal amplification for foodborne pathogen detection
AA Sayad, F Ibrahim, SM Uddin, KX Pei, MS Mohktar, M Madou, ...
Sensors and Actuators B: Chemical 227, 600-609, 2016
1542016
Microsphere integrated microfluidic disk: synergy of two techniques for rapid and ultrasensitive dengue detection
S Hosseini, MM Aeinehvand, SM Uddin, A Benzina, HA Rothan, R Yusof, ...
Scientific reports 5 (1), 16485, 2015
442015
A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform
SM Uddin, F Ibrahim, AA Sayad, A Thiha, KX Pei, MS Mohktar, U Hashim, ...
Sensors 15 (3), 5376-5389, 2015
422015
Ultrasensitive and label-free biosensor for the detection of Plasmodium falciparum histidine-rich protein II in saliva
GV Soraya, CD Abeyrathne, C Buffet, DH Huynh, SM Uddin, J Chan, ...
Scientific reports 9 (1), 17495, 2019
242019
A magnetoimpedance biosensor microfluidic platform for detection of glial fibrillary acidic protein in blood for acute stroke classification
A Sayad, SM Uddin, S Yao, H Wilson, J Chan, H Zhao, G Donnan, ...
Biosensors and Bioelectronics 211, 114410, 2022
122022
Heater integrated lab-on-a-chip device for rapid HLA alleles amplification towards prevention of drug hypersensitivity
SM Uddin, A Sayad, J Chan, DH Huynh, E Skafidas, P Kwan
Sensors 21 (10), 3413, 2021
72021
Meander thin-film biosensor fabrication to investigate the influence of structural parameters on the magneto-impedance effect
A Sayad, SM Uddin, J Chan, E Skafidas, P Kwan
Sensors 21 (19), 6514, 2021
62021
Rapid detection of HLA-B* 57: 01-expressing cells using a label-free interdigitated electrode biosensor platform for prevention of abacavir Hypersensitivity in HIV treatment
J Chan, GV Soraya, L Craig, SM Uddin, M Todaro, DH Huynh, ...
Sensors 19 (16), 3543, 2019
42019
Case study: Tidal current energy potential in Bangladesh
NH Samrat, N Mamun, SM Uddin, A Islam
2013 International Conference on Informatics, Electronics and Vision (ICIEV …, 2013
42013
Design and Optimisation of Elliptical-Shaped Planar Hall Sensor for Biomedical Applications
SM Uddin, A Sayad, J Chan, E Skafidas, P Kwan
Biosensors 12 (2), 108, 2022
22022
Optimization of the Amplicons Detection System of Loop-Mediated Isothermal Amplification on Microfluidic Compact Disk
SM Uddin, F Ibrahim, J Cho, KL Thong
International Conference on Biomedical and Health Informatics: ICBHI 2015 …, 2019
12019
Development of a Detection System for Loop Mediated Isothermal Amplification on Centrifugal Microfluidic Platform
SM Uddin
Jabatan Kejuruteraan Bioperubatan, Fakulti Kejuruteraan, Universiti Malaya, 2016
2016
Microsphere integrated microfluidic disk: synergy of two techniques for rapid and ultrasensitive dengue detection.
SH Samira Hosseini, MM Aeinehvand, SM Uddin, A Benzina, HA Rothan, ...
2015
El sistema no puede realizar la operación en estos momentos. Inténtalo de nuevo más tarde.
Artículos 1–14