Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition G Landry, B Reniers, L Murrer, L Lutgens, E Bloemen‐Van Gurp, ... Medical physics 37 (10), 5188-5198, 2010 | 112 | 2010 |
Extracting atomic numbers and electron densities from a dual source dual energy CT scanner: experiments and a simulation model G Landry, B Reniers, PV Granton, B van Rooijen, L Beaulieu, ... Radiotherapy and Oncology 100 (3), 375-379, 2011 | 107 | 2011 |
Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays F Verhaegen, B Reniers, F Deblois, S Devic, J Seuntjens, D Hristov Physics in Medicine & Biology 50 (15), 3555, 2005 | 104 | 2005 |
Postimplant dosimetry using a Monte Carlo dose calculation engine: a new clinical standard JF Carrier, M D’Amours, F Verhaegen, B Reniers, AG Martin, E Vigneault, ... International Journal of Radiation Oncology* Biology* Physics 68 (4), 1190-1198, 2007 | 94 | 2007 |
The radial dose function of low-energy brachytherapy seeds in different solid phantoms: comparison between calculations with the EGSnrc and MCNP4C Monte Carlo codes and … B Reniers, F Verhaegen, S Vynckier Physics in Medicine & Biology 49 (8), 1569, 2004 | 93 | 2004 |
ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy H Afsharpour, G Landry, M D’Amours, S Enger, B Reniers, E Poon, ... Physics in Medicine & Biology 57 (11), 3273, 2012 | 86 | 2012 |
Simulation study on potential accuracy gains from dual energy CT tissue segmentation for low-energy brachytherapy Monte Carlo dose calculations G Landry, PV Granton, B Reniers, MC Öllers, L Beaulieu, JE Wildberger, ... Physics in Medicine & Biology 56 (19), 6257, 2011 | 77 | 2011 |
Dosimetric characterization of a novel intracavitary mold applicator for high dose rate endorectal brachytherapy treatment E Poon, B Reniers, S Devic, T Vuong, F Verhaegen Medical physics 33 (12), 4515-4526, 2006 | 66 | 2006 |
The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources G Landry, B Reniers, JP Pignol, L Beaulieu, F Verhaegen Medical physics 38 (3), 1526-1533, 2011 | 61 | 2011 |
Calculation of relative biological effectiveness of a low-energy electronic brachytherapy source B Reniers, D Liu, T Rusch, F Verhaegen Physics in Medicine & Biology 53 (24), 7125, 2008 | 58 | 2008 |
Spectroscopic characterization of a novel electronic brachytherapy system D Liu, E Poon, M Bazalova, B Reniers, M Evans, T Rusch, F Verhaegen Physics in Medicine & Biology 53 (1), 61, 2007 | 57 | 2007 |
Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant H Afsharpour, JP Pignol, B Keller, JF Carrier, B Reniers, F Verhaegen, ... Physics in Medicine & Biology 55 (16), 4547, 2010 | 55 | 2010 |
A tumor DNA complex aberration index is an independent predictor of survival in breast and ovarian cancer HKM Vollan, OM Rueda, SF Chin, C Curtis, G Turashvili, S Shah, ... Molecular oncology 9 (1), 115-127, 2015 | 53 | 2015 |
Dosimetric study of the new InterSource125 iodine seed B Reniers, S Vynckier, P Scalliet Medical physics 28 (11), 2285-2288, 2001 | 51 | 2001 |
Online pretreatment verification of high-dose rate brachytherapy using an imaging panel GP Fonseca, M Podesta, M Bellezzo, MR Van den Bosch, L Lutgens, ... Physics in Medicine & Biology 62 (13), 5440, 2017 | 50 | 2017 |
Comparison of TG‐43 and TG‐186 in breast irradiation using a low energy electronic brachytherapy source SA White, G Landry, GP Fonseca, R Holt, T Rusch, L Beaulieu, ... Medical physics 41 (6Part1), 061701, 2014 | 46 | 2014 |
Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant C Furstoss, B Reniers, MJ Bertrand, E Poon, JF Carrier, BM Keller, ... Medical physics 36 (5), 1848-1858, 2009 | 43 | 2009 |
In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study B Reniers, G Landry, R Eichner, A Hallil, F Verhaegen Medical physics 39 (4), 1925-1935, 2012 | 42 | 2012 |
Preclinical assessment of efficacy of radiation dose painting based on intratumoral FDG-PET uptake D Trani, A Yaromina, L Dubois, M Granzier, SGJA Peeters, R Biemans, ... Clinical Cancer Research 21 (24), 5511-5518, 2015 | 39 | 2015 |
Residual metabolic tumor activity after chemo-radiotherapy is mainly located in initially high FDG uptake areas in rectal cancer J van den Bogaard, MHM Janssen, G Janssens, J Buijsen, B Reniers, ... Radiotherapy and oncology 99 (2), 137-141, 2011 | 37 | 2011 |