Follow
Leonardo M. Angelone
Title
Cited by
Cited by
Year
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck.
MI Iacono, E Neufeld, E Akinnagbe, K Bower, J Wolf, OI Vogiatzis, ...
PloS one 10 (4), e0124126, 2015
2792015
Multimodal integration of high-resolution EEG and functional magnetic resonance imaging data: a simulation study
F Babiloni, C Babiloni, F Carducci, GL Romani, PM Rossini, LM Angelone, ...
Neuroimage 19 (1), 1-15, 2003
1562003
RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: The role of surgical lead management
L Golestanirad, J Kirsch, G Bonmassar, S Downs, B Elahi, A Martin, ...
NeuroImage 184, 566-576, 2019
1202019
Metallic electrodes and leads in simultaneous EEG‐MRI: Specific absorption rate (SAR) simulation studies
LM Angelone, A Potthast, F Segonne, S Iwaki, JW Belliveau, ...
Bioelectromagnetics 25 (4), 285-295, 2004
1152004
MRI-based anatomical model of the human head for specific absorption rate mapping
N Makris, L Angelone, S Tulloch, S Sorg, J Kaiser, D Kennedy, ...
Medical & biological engineering & computing 46, 1239-1251, 2008
1072008
Local SAR near deep brain stimulation (DBS) electrodes at 64 and 127 MHz: A simulation study of the effect of extracranial loops
L Golestanirad, LM Angelone, MI Iacono, H Katnani, LL Wald, ...
Magnetic resonance in medicine 78 (4), 1558-1565, 2017
1042017
A Novel Brain Stimulation Technology Provides Compatibility with MRI
P Serano, LM Angelone, H Katnani, E Eskandar, G Bonmassar
Scientific reports 5, 2015
922015
Feasibility of using linearly polarized rotating birdcage transmitters and close‐fitting receive arrays in MRI to reduce SAR in the vicinity of deep brain simulation implants
L Golestanirad, B Keil, LM Angelone, G Bonmassar, A Mareyam, LL Wald
Magnetic resonance in medicine 77 (4), 1701-1712, 2017
912017
Specific absorption rate studies of the parallel transmission of inner‐volume excitations at 7T
AC Zelinski, LM Angelone, VK Goyal, G Bonmassar, E Adalsteinsson, ...
Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2008
882008
EEG/(f) MRI measurements at 7 Tesla using a new EEG cap (“InkCap”)
CE Vasios, LM Angelone, PL Purdon, J Ahveninen, JW Belliveau, ...
Neuroimage 33 (4), 1082-1092, 2006
842006
Construction and modeling of a reconfigurable MRI coil for lowering SAR in patients with deep brain stimulation implants
L Golestanirad, MI Iacono, B Keil, LM Angelone, G Bonmassar, MD Fox, ...
NeuroImage 147, 577-588, 2017
792017
Multimodal integration of EEG and MEG data: A simulation study with variable signal‐to‐noise ratio and number of sensors
F Babiloni, C Babiloni, F Carducci, GL Romani, PM Rossini, LM Angelone, ...
Human brain mapping 22 (1), 52-62, 2004
742004
The Role of Computational Modeling and Simulation in the Total Product Life Cycle of Peripheral Vascular Devices
TM Morrison, ML Dreher, S Nagaraja, LM Angelone, W Kainz
Journal of medical devices 11 (2), 024503, 2017
722017
On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies
LM Angelone, CE Vasios, G Wiggins, PL Purdon, G Bonmassar
Magnetic resonance imaging 24 (6), 801-812, 2006
682006
Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI
LM Angelone, J Ahveninen, JW Belliveau, G Bonmassar
Medical Imaging, IEEE Transactions on 29 (4), 1029-1038, 2010
652010
Reducing RF-Induced Heating Near Implanted Leads Through High-Dielectric Capacitive Bleeding of Current (CBLOC)
L Golestanirad, LM Angelone, J Kirsch, S Downs, B Keil, G Bonmassar, ...
IEEE Transactions on Microwave Theory and Techniques 67 (3), 1265-1273, 2019
632019
Changes in the specific absorption rate (SAR) of radiofrequency energy in patients with retained cardiac leads during MRI at 1.5 T and 3T
L Golestanirad, AA Rahsepar, JE Kirsch, K Suwa, JC Collins, ...
Magnetic resonance in medicine 81 (1), 653-669, 2019
572019
Retrospective analysis of RF heating measurements of passive medical implants
T Song, Z Xu, MI Iacono, LM Angelone, S Rajan
Magnetic resonance in medicine 80 (6), 2726-2730, 2018
492018
Assessing the Electromagnetic Fields Generated By a Radiofrequency MRI Body Coil at 64 MHz: Defeaturing Versus Accuracy
E Lucano, M Liberti, GG Mendoza, T Lloyd, MI Iacono, F Apollonio, ...
IEEE Transactions on Biomedical Engineering 63 (8), 1591-1601, 2016
482016
On the measurement of electrical impedance spectroscopy (EIS) of the human head
G Bonmassar, S Iwaki, G Goldmakher, LM Angelone, JW Belliveau, ...
International journal of bioelectromagnetism 12 (1), 32, 2010
462010
The system can't perform the operation now. Try again later.
Articles 1–20